Control4 Shelly - Setting Up Shelly BLU / BTHome Devices
Requirements
- Chowmain Shelly Driver 20260407
- Control4 OS 3.4.0 or later
- BTHome Compatible Gateway. This includes Gen3+ Devices, BLU Gateway (Gen 3 or later) or Shelly Pro (Gen 2 or Later).
Shelly Gateway BLU Gen 1 is NOT supported as a supported BTHome gateway. Gen 3 or Later is supported
Setup
- Shelly BLU devices are implemented in Control4 using BTHome. BLE is not supported directly
- Ensure all Shelly Network devices used as BTHome Gateways are setup and working correctly in Control4
- For greater redundancy, it is recommended to add the BTHome device to multiple Shelly BTHome Gateway Devices. This can also be used for determining basic device location within the home using the CLOSEST_GATEWAY_ID variables (available in driver version 20260408 or later)
- It recommended to update the firmware using Shelly's BLE Debug App before attempting integration:
- Add the new BTHome Agent to Control4, and Auto Setup devices (in the
Agents Tab). The available BTHome devices should show as available:
- For more advanced control capabilities, BTHome devices will add
SHELLY_COMPONENT connections and other bindings which can be bound to the Shelly Component
Controller driver or other drivers for more advanced control/integration.
Related Articles
CONTROL4 SHELLY SUITE: Device Compatibility
The following devices have been tested with the Control4 Shelly Suite Driver. Please Note, this list is by no means comprehensive and due to Shelly's new component based design in Shelly Gen 2+ and Pro (Gen2+) modules, newly released WiFi / Network ...
Control4 Shelly Suite: Shelly Incorrectly Shows All Customers Devices
For Shelly Agent to differentiate different systems correctly, Customers must use a different Shelly cloud email login for Shelly Cloud. If customers have multiple Control4 systems, it is also generally recommended to have a different account login ...
Control4 Shelly Suite: Shelly Best Practices
Security and Authentication We strongly recommend against combining customer systems into the same Shelly Cloud email login account, particularly for Control4 setups using Shelly Cloud Authentication. This may affect security of all systems, and if ...
Control4 Shelly: Obtaining An API Key
Benefits of Shelly Cloud To facilitate Setup of Shelly, it is recommended to use our Shelly Agent and setup Shelly Cloud. This provides fast setup of devices, IP self-healing and better handling of sleepy devices. Chowmain's Shelly Driver suite will ...
Control4 Shelly: System Requirements
Light V2 requires a minimum OS 3.3.0. All other drivers require OS 3.2.1 minimum. (OS 3.4.3 or later is strongly recommended. X4 is supported). Shelly NG devices require OS 3.3.0 or later for compatibility with firmware 1.8 due to Control4 ...